| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
Methods based on the Loewe additivity model include the isobologram first described in 1872 (3) , the interaction index calculation (4) , the median effect method (5) , and several three-dimensional surface-response models (6 , 7) . The isobologram method evaluates the interaction at a chosen effect level and is therefore useful to inspect the drug interaction at the corresponding concentration, often the median effect concentration. The surface response methods are more complex in their calculations and have not gained wide usage. The median effect method is the most commonly used; the original publication by Chou and Talalay (5) has >900 citations, and the derived software program to calculate combination indices (CI) is widely used. The following provides an overview of the isobologram and CI analyses of drug interaction based on concentration-effect data.
The drug-induced effect, E, is described by the Hill Equation (equation A
; refs. 8
, 9
):
![]() |
The isobologram analysis evaluates the nature of interaction of two drugs, i.e., drug A and drug B, as follows (10) . First, the concentrations of drugs A and B required to produce a defined single-agent effect (e.g., IC50), when used as single agents, are placed on the x and y axes in a two-coordinate plot, corresponding to (CA, 0) and (0, CB), respectively. The line connecting these two points is the line of additivity. Second, the concentrations of the two drugs used in combination to provide the same effect, denoted as (cA, cB), are placed in the same plot. Synergy, additivity, or antagonism are indicated when (cA, cB) is located below, on, or above the line, respectively.
CI analysis, similar to isobologram analysis, provides qualitative information on the nature of drug interaction, and CI, a numerical value calculated as described in equation B
, also provides a quantitative measure of the extent of drug interaction.
![]() |
CA,x and CB,x are the concentrations of drug A and drug B used in combination to achieve x% drug effect. ICx,A and ICx,B are the concentrations for single agents to achieve the same effect. A CI of less than, equal to, and more than 1 indicates synergy, additivity, and antagonism, respectively.
In the Chou and Talalay method, the concentration-effect curve described by equation A
is linearized by logarithmic transformation as shown by equation C
(5)
:
![]() |
Although isobologram and CI analyses provide information on the nature and extent of drug interaction at different concentrations of the drugs used in combination and/or at different effect levels, neither method provides the conventional, investigator-friendly plots of drug concentration-effect curves commonly used in pharmacological studies. In isobologram analysis, a separate plot is presented for each effect level and includes only the concentrations of the drugs in combination to produce the specified effect. The typical plots provided by CI analysis as used in the Chou and Talalay method show CI as a function of effect levels and do not include the corresponding drug concentrations either as single agents or combinations. Furthermore, isobologram and CI plots, because they are based on values (e.g., CI) calculated with the IC values derived from the concentration-effect curves, do not provide information on the variability of the actual data. Accordingly, an investigator would not be able to decide with confidence that the extent of synergy or antagonism indicated by these plots is significant compared with the data variability.
On the other hand, plots of effects as a function of concentrations enable an investigator to visually inspect data variability, goodness of fit by regression analysis. Hence, the second goal of the present study was to develop a nonlinear regression-based method and the associated computer program/algorithm that enable curve shift analysis and capture the strengths of isobologram and CI analyses. An earlier version of the computer program had been published (11) .
| MATERIALS AND METHODS |
|---|
|
|
|---|
The rationale for using suramin was to enhance the tumor sensitivity to doxorubicin based on our earlier observations (12, 13, 14) . This study used the fixed ratio method, where the doxorubicin and suramin concentrations were present in fixed ratios of concentrations corresponding to the IC50 equivalents of single agents. The stock solutions contained 0, 160, 320, 640, and 1280 µmol/L suramin combined with 10,000 nmol/L doxorubicin, representing approximate suramin-to-doxorubicin IC50-equivalent ratios of 0, 1:400, 1:200, 1:100, and 1:50, respectively (referred to as S1D400 and so on). Cells were treated with serial dilutions (10- to 100,000-fold diluted) of the stock solutions. Controls were processed similarly but without drugs. The concentrations of single-agent suramin treatment were 0, 10, 50, 100, 500, and 1000 µmol/L. The results were analyzed with linear and nonlinear regressions to obtain the corresponding IC50 and n (see below).
General Strategy for Simulations.
We examined the effects of data transformation on regression-derived IC50 and n values, sensitivity of these parameters to data variability at low and high effect levels (i.e., <10% and >90%), and the calculated CI values. These studies were done with computer simulations. The parameters used to generate simulated data were selected based on or derived from experimental data, where appropriate. The general simulation strategy was to first select appropriate values for the parameters (i.e., IC50, n, effect data variability expressed as
, and CI). These values, referred to as true values, were then used together with simulations to generate sets of concentration-effect curves, which were subsequently analyzed with linear or nonlinear regression. A comparison of the analysis results with true values indicated the precision and accuracy of the two regression methods. Note that simulation of a drug concentration-effect curve requires only IC50 and n values.
Effect of Logarithmic Data Transformation on Accuracy and Precision of IC50 and n Values Obtained from Regression Analyses.
Fig. 1
outlines the procedures. For this study, the concentration-response curves were generated with arbitrarily chosen IC50 and n values. Monte-Carlo simulations were used to generate variability or error-containing concentration-effect curves for single agents according to equations A
and B
, with equation D
:
![]() |
is the normally distributed error with a mean value of 0. The SD for
ranged from 0.1 to 5%. The simulations used 10 concentrations, which cover the conventional six to eight concentrations used in concentration-response experiments (typically performed in 96-well plates).
|
|
For this purpose, the IC50 and n values obtained from the experimental data for single-agent doxorubicin (70 nmol/L and 0.6, respectively) were used to simulate a concentration-effect curve and thereby identify the effects at 1 and 10,000 nmol/L doxorubicin concentration (equaling 7.2 and 95.5%, respectively). For comparison and to show the substantial effects of data variation at these high and low drug effect levels, we also calculated the concentration where the effect is near the median value, i.e., 100 nmol/L producing 55.5% effect. These effect values were then altered to include an error of up to one experimentally observed SD, which was 4% at <10% effect level, 3% at 55% effect level, and 1% at >90% effect level, and thereby generated effect levels between 3.2 and 11.2% at 1 nmol/L, between 52.3 and 58.3% at 100 nmol/L, and between 94.5 and 96.5% at 10,000 nmol/L. These error-containing effects levels and the corresponding concentrations were substituted into the original data set, and the resulting concentration-effect curves for single agents and combinations were analyzed with linear and nonlinear regressions to obtain IC50 and n values.
Effect of Logarithmic Data Transformation on Sensitivity of CI Values to Data Variability.
Fig. 2B
outlines the procedures. Note that the methods are nearly identical to those outlined for the study of effects of logarithmic data transformation on the accuracy and precision of the calculated CI (Fig. 2A)
, with the exception of adding and subtracting from the effect (5%) a value (4%) equal to one experimentally observed SD. Also note that subtracting >5% SD value will result in negative drug effect, and it will not be possible to obtain the transformed effect by log(fa1 1)1.
Development of Curve Shift Analysis and Its Incorporation with Isobologram and CI Analyses to Analyze Drug-Drug Interaction.
We developed a curve shift method, in conjunction with isobologram and CI analyses, to analyze drug interaction. A computer program, written in SAS language and published elsewhere (6)
, was implemented to capture the strengths of all three analyses. The algorithm is outlined in Fig. 3
. The applicability of this new method was shown with, as an example, experimentally obtained results of the doxorubicin/suramin combination study. Furthermore, the results of the studies outlined above indicated that logarithmic data transformation compromised data distribution and analysis, thereby introducing errors in regression-derived IC50, n, and CI values, whereas these problems were avoided by using nonlinear regression analysis. Hence, we elected nonlinear regression for subsequent studies and method development.
|
![]() |
Substituting equation E
into equation A
yields equation F
, which describes the effects of combination therapy as a function of IC50-equivalent concentrations. IC50,combo and ncombo are the values for the combination therapy.
![]() |
Plotting the effects of single agents and combinations against IC50-equivalent drug concentrations enabled the simultaneous presentation of these concentration-effect curves in a single plot.
Computer Software Packages and Procedures.
All programming codes, graphical representations and calculations used SAS language and procedures (SAS, Cary, NC). Linear and nonlinear regressions were done with the SAS/STAT Proc REG routine and the SAS/STAT Proc NLIN routine with the Marquardt iteration method, respectively. The output of the drug-drug interaction results obtained from the 96-well microplate reader was used as input to simultaneously perform curve shift, isobologram, and CI analyses, as outlined in Fig. 3
.
A pilot study evaluated whether the quality of data fitting could be improved by weighing the data with 1/concentration as the weight. The results showed no significant improvement. Accordingly, simple regression was used.
| RESULTS |
|---|
|
|
|---|
|
Effect of Logarithmic Data Transformation on Accuracy and Precision of Regression Results: IC50 and n Values for a Single Agent.
Table 1
summarizes the results. The nonlinear regression method overestimated the IC50 and n values in 16 of 20 cases, whereas the linear regression underestimated these values in 15 of 20 cases. There are also substantial qualitative and quantitative differences between the linear and nonlinear regression results as follows.
|
14% at n of 2.0. For both regression methods, the deviations for IC50 and n were higher at higher SDs. At 2 versus 5% SD, the respective average deviations were 0.6 versus 5.7% and 0.6 versus 3.9% for the nonlinear regression results and 8.0 versus 10.0 and 22.0 versus 30.5% for the linear regression results.
Precision of the regression results is indicated by the coefficient of variation (CV) of the mean values. The average CV was comparable for both regression methods, at
8% (Table 2)
, but greater CV values were observed for the nonlinear regression results for the steeper curves at n value of
1.5.
|
Effect of Logarithmic Data Transformation on Sensitivity of Regression Results to Data Variability: IC50 and n Values for a Single Agent.
The results are shown in Table 3
. Both linear and nonlinear regression results showed higher deviations from true values (i.e., 70 nmol/L for IC50 and 0.6 for n) at higher SDs (e.g., compare the deviations at 0.5x and 1x the SD). The average deviations for the nonlinear regression results at low and high effect levels (i.e.,7.2 and 95.2%) remained negligible at an average of 3.4% for IC50 and 4.1% for n. In contrast, the deviations for the linear regression results were
5.7-fold higher at 19.4% for IC50 and 1.8-fold higher at 7.3% for n. In comparison, the parameter values derived from linear regression were less sensitive to the change at the mid effect level of 55% (average deviations of 2.4% for IC50 and 0.57% for n).
|
|
3-fold greater for linear regression. On the contrary, a 4% increase in the 5% effect level resulted in underestimated CI values at lower effect levels (
30% for nonlinear regression and
70% for linear regression) and overestimated CI values at higher effect levels; the magnitude of over- or underestimation increased with the departure of the effect level away from the median effect level. With respect to precision, either increasing or decreasing the 5% effect by 4% resulted in greater SDs in the linear regression results, at all effect levels, as compared with nonlinear regression results. A comparison of the SD values in the linear regression results, under the scenarios of perfect data or error-containing data, additionally showed highest SD values or lowest precision in the regression-derived CI values when the 5% effect contained a 4% upward error.
The data in Table 2
also show the relationship between data variation and the regression-derived IC50, n, and CI values. As discussed above, the nonlinear regression method is less sensitive to data variability at <10% and >90% effect levels and thereby yielded IC50 values that were closely aligned with true IC50 values. In contrast, the linear re-gression method is highly sensitive to these data variations; when the 5% effect was reduced erroneously by 4 to 1%, the concentration-effect curve was shifted downward and thereby resulted in underestimated IC50 value. As stated in equation B
, an underestimated IC50 value results in overestimated CI value. Conversely, when the 5% was increased erroneously to 9%, the concentration-effect curve was shifted upward, thereby overestimating the IC50 value and underestimating the CI value. This explains the higher accuracy and precision associated with the nonlinear regression results.
Integration of Nonlinear Regression-Based Curve Shift Analysis, Isobologram, and Combination Analyses to Evaluate Drug-Drug Interactions.
Fig. 6
shows the output of data analysis with the algorithm outlined in Fig. 3
. The results of linear and nonlinear regression analyses are also shown for comparison.
|
Fig. 6B
shows the isobolograms for the 50% effect level. Both linear and nonlinear regression results show that the IC50-equivalent concentrations for various suramin/doxorubicin combinations were located below the line of additivity, indicating synergistic interaction at all combinations. The separation of the points in the isobologram was consistent with that in the CI-effect plot. For example, both isobologram and CI analyses showed a wider separation between the combinations S1D200 and S1D400 analyzed by nonlinear versus linear regression.
Fig. 6C
shows the CI values. Both regression methods showed CI values < 1 in nearly all cases and thereby identified synergy between suramin and doxorubicin at various combination ratios. However, the CI values obtained with linear regression were lower than the values obtained with nonlinear regression at 10 to 80% effect levels and were higher only at 90% effect level.
Note that the three analysis methods, although each provided different types of information on drug interaction, consistently identified the two combinations, S1D50 and S1D100, corresponding to respective suramin-to-doxorubicin concentration ratios of 1:50 and 1:100, as the most synergistic combinations (i.e., the greatest leftward shift in the curve shift analysis, the greatest distance from the line of additivity in the isobologram analysis, and the lowest CI values).
To additionally illustrate the effects of logarithmic data transformation on the CI values, we compared the linear regression results to the nonlinear regression results with the latter as the reference values. The comparison showed that linear regression resulted in under- or overestimation of the CI values, depending on the effect levels and the combination ratios of the two drugs. In general, the linear regression results showed lower CI values at 10 to 70% effect levels, with greater underestimation at lower effect levels; CI was underestimated, on average, by
45% at 50% effect levels and by
75% at 10% effect level. This trend was reversed at the 90% effect level, where the linear regression results overestimated the average CI by
45%.
| DISCUSSION |
|---|
|
|
|---|
Data variability at <10% and >90% effect levels introduced significant errors in the IC50 and n values. This problem was especially critical for data analyzed with the linear regression method. At 2 to 4% variability at these effect levels, the deviations of the regression-derived IC50 and n values from their true values were
6- and
2-fold greater, respectively, compared with the nonlinear regression results. In contrast, the IC50 and n values were less sensitive to variability in the data at about median effect level. This is because small changes in fa results in large changes in log(fa1 1)1 when fa approaches 0 or 1 during logarithmic transformation. On the other hand, according to the D-optimality design method, these data points are important for reducing the variance associated with the parameter estimates and must be included in the analysis (15)
. Accordingly, we have three recommendations: (a) use nonlinear regression for data analysis, (b) increase the number of replicates to reduce the variability of data at the two ends of the concentration-effect curve, and (c) exercise care to incorporate the variability of the data at the low and high effect levels in deciding on the quality of the regression results (e.g., higher variability indicates less reliable results).
As shown in Table 2
, at n values of between 1 to 1.5, which represent the curve shape parameter for most drugs, the linear regression typically and significantly underestimated the IC50 values by
11%, whereas the nonlinear regression underestimated the values by
4%. As IC50 values are used to calculate the CI, the lower accuracy of the linear regression results also affected the accuracy and precision of the calculated CI values. Our results generated with concentration-effect data simulated with true CI values of 0.2 to 0.8 indicate the following. With perfect data, both linear and nonlinear regression methods were comparably accurate in the CI determination, although the linear regression results were less precise. Second, data variation at <10% and >90% effect levels reduced the accuracy and precision of the regression-derived CI values by both regression methods, with much lower accuracy and lower precision for linear regression. The extent of underestimation or overestimation in the CI values was relatively high and materially important; the deviation for the nonlinear regression results (11.0 ± 11.3) was significantly lower compared with the deviation for the linear regression results (34.4 ± 27.0, P < 0.0002). As CI values are indicative of the nature of drug interactions, we conclude that the linear regression method is associated with greater errors in determining synergy or antagonism between drugs and recommend using the nonlinear regression method to analyze drug interaction.
Evaluation of synergy or antagonism of agents used in combination is an integral part of cancer chemotherapy development. Various methods contributing complementary aspects to the data analysis are available. Simultaneous use of multiple methods enhances the confidence the investigator can have in her/his conclusions. We describe here a curve shift analysis method, where the concentration-effect curves of single agents and combinations are simultaneously presented on a single plot and that thereby enables visual inspection on data variability, goodness of fit by regression analysis, and parallelism of the curves. According to Loewes principle of additivity, a leftward shift of the concentration-effect curve for a combination indicates synergy and a rightward shift indicates antagonism. The shape of the curve may additionally suggest the nature of interaction; a parallel curve shift suggests equal interactions at all concentrations or effect levels, whereas a nonparallel shift suggests concentration-dependent or effect-dependent interactions. We postulate that this may have pharmacological relevance because an anticancer drug may produce antiproliferation at low concentrations and cell kill at higher concentrations. A change in the curve shape at the different parts of the concentration-effect curve may hint at the mechanisms of drug interaction; a more shallow shape at low concentrations or effect levels for the combination, whereas the rest of the curve shows a parallel shift, when compared with single agents, would suggest a greater interaction on the antiproliferation effect. It is noted that the curve shift analysis does not provide statistical estimates of drug interaction. Quantitative statistical approaches represent an area that requires additional attention (2 , 6 , 7) .
The present study additionally described an algorithm for a nonlinear regression-based method that integrates curve shift, isobologram, and CI analyses. The incorporation of isobologram and CI analyses provides additional qualitative and quantitative information on drug interaction at different combination ratios/concentrations and different effect levels.
Finally, it is of interest to note the synergy between suramin and doxorubicin. For example, the CI values from 10 to 70% drug effect levels were between 0.1 and 0.2 (equivalent to 10- to 5-fold synergy) for the S1D50 and S1D100 combinations. The corresponding suramin concentrations under these conditions are between 30 nmol/L and 7 µmol/L. This finding is consistent with our earlier observation that low concentrations of suramin (e.g., 10 µmol/L), acting as a nonspecific inhibitor of acidic and basic fibroblast growth factors, enhance the activity of chemotherapeutic agents with diverse chemical structures and action mechanisms both in vitro and in vivo (12, 13, 14) .
In conclusion, the analysis of drug-drug interaction benefits from an evaluation by several methods, including direct visualization of the data by the curve shift analysis presented here. Furthermore, the use of nonlinear regression analysis rather than the conventional linear regression of logarithmically transformed data is essential to obtain precise results of drug-drug interaction studies.
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Requests for reprints: M. Guillaume Wientjes, College of Pharmacy, 500 West 12th Avenue, Columbus, OH 43210. Phone: (614) 292-4244; Fax: (614) 688-3223; E-mail: Wientjes.1{at}osu.edu
Received 6/ 3/04; revised 8/31/04; accepted 9/14/04.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
X. Cao, M. Bloomston, T. Zhang, W. L. Frankel, G. Jia, B. Wang, N. C. Hall, R. M. Koch, H. Cheng, M. V. Knopp, et al. Synergistic Antipancreatic Tumor Effect by Simultaneously Targeting Hypoxic Cancer Cells With HSP90 Inhibitor and Glycolysis Inhibitor Clin. Cancer Res., March 15, 2008; 14(6): 1831 - 1839. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Zhang, M. Konopleva, Y.-x. Shi, T. McQueen, D. Harris, X. Ling, Z. Estrov, A. Quintas-Cardama, D. Small, J. Cortes, et al. Mutant FLT3: A Direct Target of Sorafenib in Acute Myelogenous Leukemia J Natl Cancer Inst, February 6, 2008; 100(3): 184 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. P. Jane, D. R. Premkumar, and I. F. Pollack Coadministration of Sorafenib with Rottlerin Potently Inhibits Cell Proliferation and Migration in Human Malignant Glioma Cells J. Pharmacol. Exp. Ther., December 1, 2006; 319(3): 1070 - 1080. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Cancer Research | Clinical Cancer Research |
| Cancer Epidemiology Biomarkers & Prevention | Molecular Cancer Therapeutics |
| Molecular Cancer Research | Cancer Prevention Research |
| Cancer Prevention Journals Portal | Cancer Reviews Online |
| Annual Meeting Education Book | Meeting Abstracts Online |