
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Imaging, Diagnosis, Prognosis |
Departments of 1 Molecular Pathology, 2 Cancer Biology, 3 Biostatistics and Applied Mathematics, and 4 Gastrointestinal Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, Texas
Requests for reprints: Ryuji Kobayashi, Department of Molecular Pathology, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030. Phone: 713-745-3363; Fax: 713-794-1294; E-mail: rkobayas{at}mail.mdanderson.org.
| ABSTRACT |
|---|
|
|
|---|
400 unique ion signals were detected. Classification schemes employing as many as eight individual peaks were developed using a training set with 123 members (82 cancer patients) and a blinded validation set with 125 members (57 cancer patients). The sensitivity of the study was 88%, but the specificity was significantly lower, 75%. The reason for the low specificity becomes apparent upon protein identification of the ion signals used for the classification. The identifications reveal only common serum proteins and components of the acute phase response, including serum amyloid A,
-1-antitrypsin,
-1-antichymotrypsin, and inter-
-trypsin inhibitor.
Key Words: Protein Profiling MALDI Mass Spectrometry Pancreatic Cancer
| INTRODUCTION |
|---|
|
|
|---|
90%) of the ion signals observed in profiling experiments do not correspond to full-length, unmodified proteins, measurement of the intact molecular weights as well as sequence determinations are critical for understanding the structures and function s of these peptides and low molecular weight proteins. Therefore, we have developed analogous methods using 96-well solid-phase extraction discs for offline parallel protein fractionation followed by MALDI MS detection using any mass spectrometry platform (see Fig. 1). Also, fractionated proteins are retained for subsequent structural analysis.
|
| MATERIALS AND METHODS |
|---|
|
|
|---|
|
250 µL) were centrifuged again at 14,000 rpm for 10 minutes at 4°C to remove particulates and lipids. The 274 samples used in this study were run in four groups (60, 72, 72, and 70) over 4 days because of limits on the number of samples that could be fractionated in parallel (96) and spotted on a MALDI plate (100). The first two groups were chosen for the training set. The second two groups were used for validation. All samples were blinded to the people performing the fractionation and mass analysis. Protein Extraction and Fractionation. Before protein extraction, all samples were randomized. To increase binding capacity when compared with SELDI or pipette tipbased separations, proteins were extracted from plasma using C1896-well solid-phase extraction discs (Empore, 3M, St. Paul, MN) on a 96-well plate handling robot (Quadra96, Tomtec, Hamden, CT) using the following solvent system for washing: 2% acetonitrile and 0.1% formic acid. Aliquots of plasma (20 µL) were diluted with 100 µL of the wash solvent. After loading, the extraction discs were washed with six times with 300 µL of aqueous 2% acetonitrile with 0.1% formic acid. Two elution steps were done with 300 µL of aqueous 25% acetonitrile with 0.1% formic acid and then 300 µL of aqueous 70% acetonitrile with 0.1% formic acid, referred to as the 25% fraction and 70% fraction, respectively. The eluted protein fractions were concentrated back to the original plasma volume.
Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Protein Profiling. The eluted fractions were randomized again before MALDI MS analysis. MALDI MS analysis was done on dried droplet deposits made from mixing 1 µL of plasma protein extract with 1 µL of sinapinic acid at 30 mg/mL concentration in a solvent system of 50% methanol and 50% acetonitrile. Spectra were acquired for positive ions in linear mode using a Voyager DE-STR (Applied Biosystems, Framingham, MA) with variables optimized for myoglobin and bovine serum albumin. For the 25% acetonitrile elution, spectra were acquired only with the myoglobin-optimized method; spectra were acquired from the 70% acetonitrile fraction using both methods.
Spectra were externally calibrated using a single matrix deposit containing myoglobin and thioredoxin standards at the center of the MALDI plate. All samples were analyzed using this initial calibration to retain the same number of points (time bins) per spectrum, simplifying bioinformatics processing. Mass spectra were acquired manually, so that the maximum dynamic range could be obtained without ion signal saturation.
Bioinformatics Analysis. Individual spectra were processed using the simultaneous peak detection and baseline correction (SPDBC) algorithm developed in-house (24). This algorithm produces a separate list of peak locations, heights, widths, and signal-to-noise ratios for each spectrum. For each fraction (BSA70, MYO25, and MYO70), we aligned peaks from distinct spectra using our MatchPeaks algorithm, which first sorts the peaks in order of decreasing signal-to-noise (S/N) ratio. Alignment starts with the first peak [whose mass-to-charge ratio (m/z) is denoted by X] as an "anchor." If another peak has m/z = Y, we define the relative mass error to be |X Y|/X. The algorithm identifies two peaks if the relative mass error is <0.15% or if the number of clock-ticks separating the peak locations is at most 10; all peaks satisfying this condition are formed into a single "peak class." Next, the peak with largest S/N that has not yet been assigned to a class is used as a new anchor, and matching continues until all peaks are assigned to a new peak class. The peak lists produced by SPDBC and MatchPeaks are liberal about including potential peaks with very small S/N ratios. To focus on peak classes that are more likely to represent actual proteins, we include an additional filtering step. We only retained a eak class for further analysis if it satisfied at least one of the following conditions:
Heuristically, these numbers indicate that we have more confidence in a peak if it occurs with large S/N or if it occurs in many spectra.
We use two methods to reduce the number of peaks used in the development of a model to predict whether plasma profiles arise from pancreatic cancer patients or healthy controls. First, we perform two-sample t tests on the log-transformed heights of each peak. We compensate for multiple testing by modeling the set of Ps as a ß-uniform mixture (25). The model is used to control the false discovery rate (26). Second, we combined a genetic algorithm with Mahalanobis distance (27). Mahalanobis distance is a measure of the separation between two groups of samples; it is the main computational idea underlying linear discriminant analysis (28). As a computational tool, a genetic algorithm is a method for conducting directed random searches in order to find an (approximate) optimal solution to some problem (29, 30). In the present case, we ran the genetic algorithm 100 times to identify sets of five peaks that have large Mahalanobis distance between plasma profiles in pancreatic cancer and in healthy controls.
Peaks that were significant based on the t test or that were included in a solution by the genetic algorithm were retained for a final model-building step using an iterative, forward-selection, greedy algorithm. We began with the peak P1 that had the largest t statistic. Given a set of peaks {P1, P2, ..., Pk}, we then ordered all peak sets of the form {P1, P2, ..., Pk, Q}, as Q varies, by the Mahalanobis distance between healthy and cancer samples. If the classification error on the training set was decreased by one of the top 10 peak sets, we added this peak to the working set and continued. We stopped when the training classification error stabilized.
Protein Identification. Plasma proteins were identified in three different ways. First, one-dimensional SDS-denatured PAGE was done with 4% to 20% Criterion gels (Bio-Rad, Hercules, CA) to separate the proteins. Bands of the appropriate molecular weight were excised, digested with trypsin, and sequenced using liquid chromatography (LC)-MS/MS on an electrospray ion trap instrument (LCQ DecaXP or LTQ, Thermo, San Jose, CA). Proteins from the same C18 fractions were also separated with reverse phase high-performance liquid chromatography using a 0.5-mm ID Vydac C4 column (Hesperia, CA), followed by fraction collection, MALDI analysis to identify the fractions containing target proteins, and then tryptic digestion and LC-MS/MS of the appropriate fractions for protein identification. LC-MS/MS results were searched against the National Center for Biotechnology Information human database using a licensed copy of SONAR (Genomic Solutions, Ann Arbor, MI). Smaller proteins were also identified by direct MALDI MS/MS. Samples were preconcentrated using C18 Ziptips (Millipore, Billerica, MA) and eluted with 4 mg/mL
-cyano-4-hydroxycinnamic acid prepared in 50% aqueous acetonitrile. Tandem mass spectrometry analysis was done using a 1 kV MS/MS method on a TOF/TOF instrument (Applied Biosystems, Framingham, MA) with collision gas on and off. Several spectra consisting of 22,500 laser shots were acquired and averaged. Peak lists were generated manually and searched against the MSDB using MS-Tag with no enzyme and methionine oxidation selected (http://prospector.ucsf.edu).
Quantitative Analysis of Human Serum Amyloid A by ELISA. Serum amyloid A (SAA) levels in human plasma samples were quantified using a human SAA Immunoassay kit (BioSource International, Inc., Camarillo, CA), according to the manufacturer's instructions with minor modifications. Duplicate plasma samples were diluted 1:1,000 with the sample diluent buffer. Working conjugated anti-human SAA (1x, 50 µL) was added to each assay well that contained monoclonal antibody specific for human SAA, followed by 50 µL of either standards or samples. The plates were covered and incubated at 37°C for 1 hour. The supernatants were aspirated thoroughly, and the wells were washed thrice with 1x wash buffer. Then, working p-nitrophenyl phosphate substrate solution (100 µL), prepared just before use, was added and the plate was again covered and incubated at 37°C for 1 hour. Then, stop solution (50 µL) was added to each well. After incubating at room temperature for 30 minutes, the absorbance at 450 nm was measured for each well on a CERE UV 900C plate reader (BioTek Instruments, Winooski, VT) after zeroing with blank composed of working p-nitrophenyl phosphate substrate solution and stop solution. All samples with concentration of SAA higher than the standards were further diluted and reassayed at 1:4,000 and 1:10,000 dilutions. The concentration of SAA in each sample well was reported automatically by the instrument software built into the machine and corrected by the dilution factor.
Quantitative Analysis of Human Haptoglobin by Peroxidase Activity Assay. Haptoglobin levels in human plasma samples were quantified using a haptoglobin assay kit (BioSource International) according to the manufacturer's instructions with minor modifications. Human plasma samples were diluted at least 10-fold with calibrator diluent prior to assay. Equal volumes of hemoglobin and hemoglobin diluent were mixed (reagent 1), as were chromogen and substrate in the ratio of 9:5 (reagent 2). Calibrator standards (0-2 mg/mL) were prepared as instructed. The calibrators and unknown samples (7.5 µL) were transferred in duplicate to a 96-well microtiter plate. Reagent 1 (100 µL) was added to each well and mixed, then reagent 2 (140 µL) was added to each well. After incubation for 5 minutes at room temperature, the absorbance at 660 nm was measured on CERE UV 900C plate reader (BioTek Instruments). All samples with concentrations of haptoglobin higher than the calibrator standards were diluted further and reassayed. The concentration of haptoglobin in each sample well was reported automatically by the instrument software built into the machine and corrected by the dilution factor.
Quantitative Analysis of Human CA19.9. Measurements of the CA19.9 levels in the cancer patients' plasma samples were done in the M.D. Anderson Cancer Center clinical chemistry laboratory.
| RESULTS AND DISCUSSION |
|---|
|
|
|---|
|
To identify sets of peaks that can be used to diagnose pancreatic cancer, we also combined a genetic algorithm with Mahalanobis distance. We used the genetic algorithm to identify sets of five peaks, chosen out of the set of all 436 peaks, that have large Mahalanobis distance between the pancreatic cancer samples and the healthy controls. Because the genetic algorithm uses randomness to locate approximate maxima, it may find different answers each time it is run; therefore, 100 iterations were run from different starting points. As expected, numerous different combinations of five peaks separate normal samples from cancer samples in the training set. Peaks that were significant based on the t test with false discovery rate <1% or that were included in a solution by the genetic algorithm were used in a greedy algorithm to determine the best predictive model. The algorithm stops adding peaks when the classification error on the training set stops improving.
From the observed ion signals, eight were chosen for patient classification based on the results of the genetic algorithm and t tests (see Table 2). Zoomed views are shown for six of the eight peaks in Fig. 3; the other two, m/z 19,064 and m/z 39,892, could not be visually distinguished in the MALDI mass spectra. The sensitivity and specificity observed in the validation set for these eight peaks were 95% (54 of 57) and 70% (51 of 73), respectively. After removal of the ion signals that could not be visually observed in the MALDI profiles, the sensitivity and specificity observed in the validation set for these eight peaks were 88% (50 of 57) and 75% (55 of 73), respectively. The sensitivity and specificity for the six peaks with the addition of serum amyloid A were 88% (50 of 57) and 74% (54 of 73). These results are similar to those of other similar studies reported in the literature. The sensitivity is often quite high, but the specificity is poor with 25% to 30% false positives.
|
|
,ß) to the sensitivity and specificity; these prior distributions require us to specify two variables to control the shape and the scale of the ß distribution. It is a standard result in Bayesian statistics that the posterior distribution for the sensitivity or specificity, conditioned on correctly classifying k out of n samples in the validation data, is given by another ß distribution, B(
+ k, ß + n k). The 90% lower and upper limits for sensitivity and specificity of the six-peak model using different prior assumptions are summarized in Table 3. When
= ß = 1, we use a uniform prior, from which the 90% confidence interval for sensitivity ranges from 79.5% to 93.7%, and the 90% confidence interval for specificity ranges from 66.5% to 82.9%. We also considered alternative priors. Using
= 0.2 and ß = 1.8 is a skeptical prior, because it suggests that we start the experiment expecting only 10% of the samples to be correctly classified by the model. By contrast, the prior with
= 1.6 and ß = 0.4 is fairly aggressive, because it suggests that we start the experiment expecting about 80% of the samples to be correctly classified. In our case, the skeptical estimate yields a lower limit of 87.8% for the sensitivity and a lower limit of 65.4% for the specificity. The more aggressive estimate yields sensitivity between 80.7% and 94.4% and specificity between 67.4% and 83.6%.
|
-trypsin inhibitor heavy chain H4 (ITH4) by direct MALDI MS/MS (see Fig. 4). The sequence was the only possible match using MS-Tag and searching 14 fragment ions. The prediction of the sequence from ITH4 was consistent in mass accuracy and the cleavages were consistent with expected fragment ion chemistry (i.e., preferential cleavage at aspartic acid and proline). Additional fragment ions were identified manually to verify the proper sequence was selected. The peaks at m/z 17,240 and m/z 51,534 were identified by one-dimensional SDS-PAGE separation, in-gel digestion, and LC-MS/MS peptide sequencing. The peak at m/z 15,863 was identified by C4 high-performance liquid chromatography, fraction collection, MALDI monitoring, in-solution digestion of the appropriate fraction, and LC-MS/MS as hemoglobin ß (eight peptides). The peak at 17,240 corresponds to a fragment of apolipoprotein A-I or apolipoprotein glutamine-I (both proteins have the same sequence). Because of the width of the peak at m/z 51,534 in the MALDI profiles, it is likely to consist of a combination of proteins. Based on in-gel digestion and LC-MS/MS,
-1-antitrypsin (nine peptides),
-1-antichymotrypsin (four peptides), and haptoglobin (five peptides) could all be detected as components of this broad peak in the MALDI mass spectra (Table 4). In addition to the eight peaks described above, serum amyloid A (m/z 11,683) was identified by SDS-PAGE separation, in-gel digestion and LC-MS/MS peptide sequencing (three peptides) as well as C4 high-performance liquid chromatography separation, MALDI detection, and LC-MS/MS peptide sequencing (two peptides), after it was observed primarily in cancer patients (one exception). The entire pattern of peaks in Fig. 3D is consistent with the identification of serum amyloid A. This cluster of peaks was consistently observed in SAA+ patients. Two isoforms of SAA are observed at m/z 11,684 and m/z 11,629. The lower molecular weight peaks were identified, not by their intact molecular weights, but by the mass differences from the SAA ion signals. The molecular weights could be accurately measured to within 0.5 Da using internal calibration, the mass differences corresponding to arginine residues (156) and serine residues (87) were measured consistently and observed from both intact species. This evidence was very convincing, especially in light of the fact that this pattern of peaks was previously identified as SAA with tandem mass spectrometry after immunoprecipitation coupled to MALDI MS analysis (33).
|
|
Furthermore, using the ELISA results for serum amyloid A, a detection limit can be assessed for this MALDI profiling. We could detect SAA in almost all samples above 50 µg/mL, which corresponds to 4.28 pmol/µL and a 4.28 µmol/L solution of the SAA protein. The highest SAA concentration that the MALDI could not detect was 61.6 µg/mL (5.3 µmol/L) and the lowest it could detect was 20.9 µg/mL (1.8 µmol/L). These results compare favorably to the practical limits of instrument performance (protein detection at 100 fmol to 1 pmol), considering the source of the protein, its presence in an extremely complex mixture, and the fact that it is processed in plasma and thus seems as multiple peaks in the MALDI mass spectra (see Fig. 3D). This result is very important because it links the MALDI data to concentration measurements and is consistent with the claim that protein profiling using simple fractionation coupled to direct MALDI MS analysis will not be able to detect proteins which are low in abundance (31, 32).
| CONCLUSIONS |
|---|
|
|
|---|
at m/z 15,127 was less than +6 across the entire sample set; both of these values are below a mass measurement error of 0.05%. With internal calibration, mass measurement error could be decreased to <0.01% (100 ppm) for these peptides and low molecular weight proteins. Furthermore, we have established the detection limits of this technique to be at the level of a 5 µmol/L protein concentration by comparison of the MALDI mass spectra and ELISA measurements of serum amyloid A. This value compares favorably to the practical limits for detection of an individual protein in a protein mixture with MALDI TOFMS (hundreds of femtomoles to a few picomoles), because of the observation of SAA as several peaks due to NH2-terminal modification (33) and the complexity and contamination of the protein's source, plasma. In addition to improving the characteristics of the protein profiling experiment, the utility of sequencing by direct MALDI MS/MS was shown in the identification of the ion signal at m/z 4,284 observed at higher intensity in controls as a fragment of inter-
-trypsin inhibitor H4. A similar peak was observed in a SELDI study of pancreatic cancer (m/z 4,277), but the identity was not reported in that study (34). Direct MALDI MS/MS is a useful tool for obtaining sequence information and establishing validity for the ion signals observed in these protein profiles.
Despite significant improvements in the protein fractionation and mass spectrometry, the classification results are similar to those of other plasma or serum protein profiling studies reported in the literature. The sensitivity is often quite high (<90%), but the specificity is not sufficient (70-75%). A test with these characteristics gives too many false positives, perhaps leading clinicians to give unnecessary treatment. The low specificity is consistent with the protein identifications: the proteins do not have specific roles in pancreatic cancer, but rather in host response. SAA and haptoglobin are constituents of the acute phase response. Despite prior reports which link these proteins to cancer (3543), we believe that these proteins will not be specific enough for cancer diagnosis, because they are also observed in other diseases involving inflammation, including coronary disease and bacterial infection (4448). Indeed, measurements of plasma haptoglobin were not useful for diagnosis of pancreatic cancer in the population studied here. Based on the increased levels of SAA in a subset of cancer patients (
30%), 7 of 137 (
5%) pancreatic cancer patients were diagnosed that could have been missed by CA19.9 measurements; therefore, SAA may have some value as a supplement to conventional tests. Unlike SAA and haptoglobin, increased expression of plasma protease inhibitors is consistent with and seems more specific for pancreatic cancer. Furthermore, the serpins,
-1-antitrypsin and
-1-antichymotrypsin, have been directly linked to pancreatic cancer (4954). However, the important caveat is that these proteins also play a role in the acute phase response, so we can not conclusively state that a specific diagnostic marker is being observed. Based on these protein identities and the previous literature (4954), it is unlikely that these markers are specific for diagnosis of pancreatic cancer. The unidentified peaks (m/z 8,204 and m/z 9,351) are too high in m/z for direct MALDI MS/MS and they have proven to be difficult to isolate chromatographically.
Although improvements were made to the fractionation and mass analysis and differences could be detected between cancer patients and corresponding controls, critical limitations still exist for this technology. The sensitivity of MALDI protein profiling remains poor when compared with antibody-based methods, as previously pointed out by Diamandis (31, 32). Furthermore, protein profiling experiments are restricted to the limited mass range for protein detection with MALDI TOF MS (most ion signals between m/z 2,000 and m/z 30,000). In the future, we will pursue other analytic methods, including profiling enzymatic digests of plasma proteins, which not only increase the sensitivity and widen the accessible mass range for the protein detection, but also enable direct identification using tandem mass spectrometry peptide sequencing.
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Note: J. Koomen and L. Nancy Shih contributed equally to this work.
Received 6/28/04; revised 9/16/04; accepted 9/29/04.
| REFERENCES |
|---|
|
|
|---|
subunit as potential serum biomarker in ovarian cancer: identification and characterization using proteomic profiling and mass spectrometry. Clin Cancer Res 2003;9:290411.
-1-antitrypsin, glutathione S-transferase pi and vascular endothelial growth factor in human pancreatic adenocarcinoma. Am J Surg 2002;184:6428.[CrossRef][Medline]
1-Antitrypsin and survival in pancreatic cancer. Int J Cancer 1990;45:6856.[Medline]
1-Antitrypsin in pancreatic diseases. Digestion 1978;18:13840.[Medline]This article has been cited by other articles:
![]() |
A. Gammerman, V. Vovk, B. Burford, I. Nouretdinov, Z. Luo, A. Chervonenkis, M. Waterfield, R. Cramer, P. Tempst, J. Villanueva, et al. Serum Proteomic Abnormality Predating Screen Detection of Ovarian Cancer The Computer Journal, April 15, 2008; (2008) bxn021v3. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Tang, K. Kitisin, W. Jogunoori, C. Li, C.-X. Deng, S. C. Mueller, H. W. Ressom, A. Rashid, A. R. He, J. S. Mendelson, et al. Progenitor/stem cells give rise to liver cancer due to aberrant TGF-{beta} and IL-6 signaling PNAS, February 19, 2008; 105(7): 2445 - 2450. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Keller, N. Comtesse, N. Ludwig, E. Meese, and H.-P. Lenhof SePaCS--a web-based application for classification of seroreactivity profiles Nucleic Acids Res., July 13, 2007; 35(suppl_2): W683 - W687. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Timms, E. Arslan-Low, A. Gentry-Maharaj, Z. Luo, D. T'Jampens, V. N. Podust, J. Ford, E. T. Fung, A. Gammerman, I. Jacobs, et al. Preanalytic Influence of Sample Handling on SELDI-TOF Serum Protein Profiles Clin. Chem., April 1, 2007; 53(4): 645 - 656. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. V. Karpievitch, E. G. Hill, A. J. Smolka, J. S. Morris, K. R. Coombes, K. A. Baggerly, and J. S. Almeida PrepMS: TOF MS data graphical preprocessing tool Bioinformatics, January 15, 2007; 23(2): 264 - 265. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Hortin The MALDI-TOF Mass Spectrometric View of the Plasma Proteome and Peptidome Clin. Chem., July 1, 2006; 52(7): 1223 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Song, M. Patel, C. N. Rosenzweig, Y. Chan-Li, L. J. Sokoll, E. T. Fung, N.-H. Choi-Miura, M. Goggins, D. W. Chan, and Z. Zhang Quantification of Fragments of Human Serum Inter-{alpha}-Trypsin Inhibitor Heavy Chain 4 by a Surface-Enhanced Laser Desorption/Ionization-Based Immunoassay Clin. Chem., June 1, 2006; 52(6): 1045 - 1053. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Ye, S. Skates, S. C. Mok, N. K. Horick, H. F. Rosenberg, A. Vitonis, D. Edwards, P. Sluss, W. K. Han, R. S. Berkowitz, et al. Proteomic-Based Discovery and Characterization of Glycosylated Eosinophil-Derived Neurotoxin and COOH-Terminal Osteopontin Fragments for Ovarian Cancer in Urine Clin. Cancer Res., January 15, 2006; 12(2): 432 - 441. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. W. Duncan and S. W. Hunsucker Proteomics as a Tool for Clinically Relevant Biomarker Discovery and Validation Experimental Biology and Medicine, December 1, 2005; 230(11): 808 - 817. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Honda, Y. Hayashida, T. Umaki, T. Okusaka, T. Kosuge, S. Kikuchi, M. Endo, A. Tsuchida, T. Aoki, T. Itoi, et al. Possible Detection of Pancreatic Cancer by Plasma Protein Profiling Cancer Res., November 15, 2005; 65(22): 10613 - 10622. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. Ressom, R. S. Varghese, M. Abdel-Hamid, S. A.-L. Eissa, D. Saha, L. Goldman, E. F. Petricoin, T. P. Conrads, T. D. Veenstra, C. A. Loffredo, et al. Analysis of mass spectral serum profiles for biomarker selection Bioinformatics, November 1, 2005; 21(21): 4039 - 4045. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Goggins Molecular Markers of Early Pancreatic Cancer J. Clin. Oncol., July 10, 2005; 23(20): 4524 - 4531. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||