
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Imaging, Diagnosis, Prognosis |
Authors' Affiliations: 1 Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, NIH, Bethesda, Maryland and 2 Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo, Japan
Requests for reprints: Hisataka Kobayashi, Molecular Imaging Program, Center for Cancer Research, National Cancer Institute/NIH, Building 10, Room 1B40, MSC 1088, 10 Center Drive, Bethesda, MD 20892-1088. Phone: 301-435-4086; Fax: 301-402-3191; E-mail: Kobayash{at}mail.nih.gov.
| Abstract |
|---|
|
|
|---|
Experimental Design: GmSA was conjugated with 20 rhodamineX molecules (GmSA-20ROX) to create a self-quenching complex, which was compared with a conjugate consisting of GmSA and a single rhodamineX (GmSA-1ROX) in ex vivo chemical activation characteristics, intracellular activation, and in vivo molecular imaging for detecting peritoneal micrometastases of SHIN3 ovarian cancer.
Results: GmSA-20ROX was five times brighter than GmSA-1ROX when incubated with SHIN3 ovarian cancer cells for 3 h. Submillimeter SHIN3 ovarian cancer implants in the peritoneal cavity were clearly visualized in vivo with spectral fluorescence imaging due to the high tumor-to-background ratio. The sensitivity and specificity of GmSA-20ROX for implant detection were determined by colocalization of the rhodamineX emission with red fluorescent protein expressed constitutively in the SHIN3 tumor implants. Among 336 lesions, sensitivity and specificity were 99%/99%, respectively, for GmSA-20ROX, whereas the results for GmSA-1ROX were only 24%/100% (n = 388), respectively, for lesions
0.8 mm or greater in diameter.
Conclusion: Self-quenched GmSA-20ROX is more efficient than previous D-galactose–targeted fluorescent conjugates.
A common approach to optimize target-to-background ratios is to use fluorophore activation wherein the fluorophore emits minimal light in the unactivated state but increases its emission several fold in the activated state. For instance, Weissleder et al. have developed a series of agents activated by tumor-associated proteases [e.g., cathepsin D and matrix metalloproteinase-2 (MMP-2)], which function to dequench the complex resulting in a multifold increase in fluorescence (9–11). As an alternative, a self-quenching avidin-3 rhodamineX probe was synthesized, which binds D-galactose receptor on cancer cells and then is internalized (5). Intracellular endosomal or lysosomal dissociation of the avidin-3 rhodamineX complex leads to "dequenching" of the 3 rhodamineX molecules, and hence, activation of the fluorophore occurs but only within live targeted cells and not in surrounding normal cells that lack the D-galactose receptor (5). Although this approach is highly sensitive for detecting cancer microfoci in vivo, the immunogenicity of avidin has been an obstacle to its translation into clinical studies (13, 14).
Recently, a galactosamine-conjugated serum albumin (GmSA) was proposed as a clinically feasible alternative to avidin, in which GmSA-based probe targets the same D-galactose receptor but is nonimmunogenic and has been extensively used in humans. GmSA, in its radiolabeled form, is used to assess hepatic reserve in Japan. GmSA has higher affinity for D-galactose based on its multivalency and its favorable high isoelectric point (7). Herein, we describe the synthesis and implementation of a self-quenching GmSA molecule with multiple rhodamineX (n
20; GmSA-20ROX), which is compared with its unquenched version (GmSA-1ROX). We evaluated the ability of GmSA-20ROX to bind cancer cells and compared the fluorescence intensity in vivo of GmSA-20ROX with GmSA-1ROX in a mouse model of ovarian cancer peritoneal metastases.
| Materials and Methods |
|---|
|
|
|---|
The rhodamineX concentrations were measured by the absorption at 595 nm with a UV-Vis system (8453 Value UV-Bis system, Agilent Technologies) to confirm the number of rhodamineX molecules conjugated with each GmSA molecule. By changing the concentration of the GmSA solution, the number of fluorophore molecules per GmSA was adjusted to be either 1 (GmSA-1ROX) or 20 (GmSA-20ROX).
The protein concentration of GmSA-ROX samples was determined by measuring the absorption at 280 nm with a UV-Vis system (8453 Value UV-Bis system) using GmSA standard solutions of known concentrations (100, 200, and 400 µg/mL). Then, the protein concentration was calculated using the absorbance value corrected by the absorbance of rhodamineX molecule at 280 nm known from the rhodamineX concentration.
Finally, to validate that, the fluorophores were associated with the respective proteins, and both conjugates were analyzed by gel filtration using a high-performance liquid chromatography system equipped with an in-line UV detector (System Gold, Beckman Coulter, Inc.) and fluorescence detector (FP2020, Jasco, Inc.) using a TSK G2000 60-cm column (TOSO Bioscience LLC) with 0.066 mol/L PBS. The UV absorbance profile of GmSA-20ROX at 280 nm was validated to be consistent with the fluorescence profile, which was measured at 610 nm for GmSA-20ROX.
Cell culture
An established ovarian cancer cell line, SHIN3 (15), was used for in vitro fluorescence microscopy, flow cytometry, and in vivo optical imaging for i.p. disseminated cancer implants. The SHIN3 cells were grown in RPMI 1640 (Life Technologies) containing 10% fetal bovine serum (Life Technologies), 0.03% L-glutamine at 37°C, 100 units/mL penicillin, and 100 µg/mL streptomycin in 5% CO2.
Transfection of red fluorescent protein (DsRed2) in the SHIN3 cell
The red fluorescent protein (RFP DsRed2)-expressing plasmid was purchased from Clontech Laboratories, Inc. The plasmid was transfected into the SHIN3 cells to validate the results with the targeted fluorophores (see below). The transfection of RFP was done with the electroporation method using Gene Plus II (Bio-Rad Laboratories). Briefly, 3 µg of DsRed2-expressing plasmid were mixed with 2 million SHIN3 cells in 400 µL of the cell culture medium (RPMI 1640 with 10% FCS). Then, the cell suspension was put in a pulse cuvette (Bio-Rad Laboratories) and 250 V pulses were delivered after 950 cycles.
Flow cytometry
One-color flow cytometry was done to compare the fluorescing capabilities of GmSA-1ROX and GmSA-20ROX in SHIN3 cancer cells. SHIN3 cells (5 x 105) were plated on a 12-chamber culture well and incubated for 16 h. GmSA-1ROX or GmSA-20ROX was added to the medium (1 µg/mL), and the cells were incubated for 30 min, 1 h, 3 h, and 6 h. Cells were washed once with PBS and trypsinized and flow cytometry was done. A 488-nm argon ion laser was used for excitation. Signals from cells were collected using a 585/42-nm band-pass filter. Cells were analyzed in a FACScan cytometer (Becton Dickinson) and all data were analyzed using CellQuest software (Becton Dickinson). The fluorescence intensity of each fluorophore was expressed as the mean fluorescence index (MFI). A regression line was calculated from the data sets of incubation time and MFI value and then plotted as a function of incubation time using Microsoft Excel 2003 (Microsoft). The MFI value at each time point and the slope of the regression line were compared between GmSA-1ROX and GmSA-20ROX (7).
Fluorescence microscopy
SHIN3 cells (2 x 104) were plated on a cover glass bottom culture well and incubated for 10 h. GmSA-1ROX or GmSA-20ROX was added to the medium (1 µg/mL) and the cells were incubated for 10 min, 30 min, or 3 h. Cells were washed once with PBS and fluorescence microscopy was done using an Olympus BX51 microscope (Olympus America, Inc.) equipped with the following filters: excitation wavelength, 530 to 570 nm, and emission wavelength, 590 nm long pass. Transmitted light differential interference contrast images were also acquired.
In vitro chemical analysis of activation
Measurement of fluorescence intensity at different acidic conditions. To compare the fluorescing capability of GmSA-1ROX and GmSA-20ROX under different acidic conditions in vitro, fluorescence intensity and emission spectra of GmSA-1ROX and GmSA-20ROX were measured with the Maestro In-Vivo Imaging System (CRi, Inc.) in arbitrary units (a.u.). GmSA-1ROX (5 µg) or GmSA-20ROX (5 µg) in 390 µL phosphate buffers with pH 2.3, 3.3, 5.2, 6.4, and 7.4 was put in a nonfluorescent 96-well plate (Costar, Corning, Inc.) and spectral fluorescence imaging was done. A band-pass filter from 503 to 555 nm and a long-pass filter over 580 nm were used for emission and excitation light, respectively. The tunable filter was automatically stepped in 10-nm increments from 500 to 800 nm while the camera captured images at each wavelength interval with constant exposure. Spectral unmixing algorithms were applied to create the unmixed image of the GmSA-1ROX and GmSA-20ROX. A region of interest (ROI) as large as each well was drawn to determine the emission spectra and the fluorescence intensity of two probes using commercial software (Maestro software, CRi). A regression line was calculated from the data sets of pH value and fluorescence intensity on unmixed images and then plotted as a function of pH value using Microsoft Excel 2003. The fluorescence intensity value at each pH and the slope of the regression line were compared between GmSA-1ROX and GmSA-20ROX (4).
Enzyme activation of fluorescence signal. Enzymatic activation of GmSA-1ROX and GmSA-20ROX by trypsin (Invitrogen), cathepsin C (Sigma-Aldrich, Inc.), cathepsin D (Sigma-Aldrich), and MMP-2 (Sigma-Aldrich) was studied. Trypsin, cathepsin C, cathepsin D, or MMP-2 dissolved in 390 µL phosphate buffers (pH 7.4 for trypsin and MMP-2, pH 6.4 for cathepsin C, and pH 4.5 for cathepsin D) was mixed with 2.5 µg GmSA-1ROX or 2.5 µg GmSA-20ROX. Concentrations of trypsin, cathepsin C, cathepsin D, and/or MMP-2 were 0.05%, 1 unit/mL, 1 unit/mL, and 1 unit/mL, respectively. The mixture was then incubated at 37°C for 0, 1, 3, and 6 h. Spectral fluorescence images were obtained using the Maestro In-Vivo Imaging System and the fluorescence signal was measured using the same method described above. To compare the fluorescence activation of GmSA-1ROX and GmSA-20ROX, the fluorescence intensity immediately after incubation with each enzyme was adjusted to be 1 in a.u. (relative signal intensity). A regression line was calculated from the data sets of relative signal intensity and incubation time and then plotted as a function of incubation time using Microsoft Excel 2003. The slope of the regression line was compared between GmSA-1ROX and GmSA-20ROX. All experiments were done in triplicate.
Detergent activation of fluorescence signal. To evaluate the dequenching ability of GmSA-20ROX, 90 µL of 20% SDS, a detergent, were added to 270 µL/5 µg of either GmSA-20ROX or GmSA-1ROX in PBS at pH 7.4 at room temperature. As control, 90 µL PBS was added to another set of samples. Immediately after mixing the SDS, spectral fluorescence images were obtained using the Maestro In-Vivo Imaging System and the fluorescence signal was measured as the same method as described above. The same experiment was repeated five times.
Additionally, 600 µL/75 µg of either GmSA-20ROX or GmSA-1ROX were placed in the plastic cuvette and excited from the bottom by a 380-nm UV lamp. The 200 µL of 20% SDS were added to each cuvette and mixed well immediately. The entire process of activation was recorded by a digital video camera (Coolpix 5100, Nikon).
Animal model of peritoneal metastases
All procedures were carried out in compliance with the Guide for the Care and Use of Laboratory Animal Resources (1996), National Research Council, and approved by the National Cancer Institute Animal Care and Use Committee. The i.p. tumor xenografts were established by i.p. injection of 2 x 106 SHIN3 or SHIN3 transfected with RFP DsRed2 cells suspended in 200 µL PBS in female nude mice (National Cancer Institute Animal Production Facility, Frederick, MD). Experiments with tumor-bearing mice were done at 14 days after injection of the cells.
In vivo spectral fluorescence imaging
GmSA-1ROX (50 µg) or GmSA-20ROX (50 µg) was diluted in 300 µL PBS and injected into the peritoneal cavities of mice with peritoneally disseminated cancer implants. Each set of two mice (one for each probe) was repeated in triplicate. Immediately, 1 and 3 h after i.p. injection, both mice were sacrificed with carbon dioxide inhalation. Immediately after sacrifice, the abdominal cavity was exposed and both mice were placed side by side on a black plate to compare the fluorescence intensity of the tumors. Spectral fluorescence images were obtained using the Maestro In-Vivo Imaging System. Whole abdominal images, as well as close-up images of the peritoneal membrane, were obtained. A band-pass filter from 503 to 555 nm and a long-pass filter over 580 nm were used for emission and excitation light, respectively. The tunable filter was automatically stepped in 10-nm increments from 500 to 800 nm while the camera captured images at each wavelength interval with constant exposure. The spectral fluorescence images consisting of autofluorescence spectra and the spectra from the probes were obtained and then unmixed based on their spectral patterns using commercial software (Maestro software).
Using the unmixed fluorescence image of the two peritoneal membranes, fluorescence intensity of the cancer implants was semiquantitatively compared between the two probes. A ROI as large as the peritoneal membrane was drawn inside the bowel, and a histogram (number of pixels at specific fluorescence intensity) was created using ImageJ software.3 Then, a threshold was set in the fluorescence intensity above which a pixel is counted. The total number of pixels (N) within the threshold range was calculated at a threshold value of t (Eq. A).
![]() | (A) |
t; ref. 4). The common logarithm (log) values of N were calculated and plotted as a function of t. The regression line was calculated from these data sets (t and logN) using Microsoft Excel 2003. For comparison of the fluorescent intensity or the "brightness," the slope of regression line was compared between the two fluorophores.
Assessment of the sensitivity and specificity of GmSA-1ROX and GmSA-20ROX for the detection of peritoneal cancer foci
Sensitivity and specificity of GmSA-1ROX and GmSA-20ROX imaging for the detection of peritoneal disseminated cancer foci were studied using three tumor-bearing mice for each probe. The i.p. tumor xenografts were established 14 days after i.p. injection of 2 x 106 RFP-transfected SHIN3 cancer cells suspended in 200 µL PBS in female nude mice (National Cancer Institute Animal Production Facility). Three hours after i.p. injection of 50 µg GmSA-1ROX or 50 µg GmSA-20ROX diluted in 300 µL PBS, spectral fluorescence images of the peritoneal membranes were obtained by Maestro In-Vivo Imaging System. For each mouse, two different parts of the peritoneal membranes were randomly selected and spread out on a black plate and close-up spectral fluorescence imaging was done. ROIs were drawn both within the nodules depicted by RFP spectral unmixed images (standard reference for cancer foci) and in the surrounding adjacent areas (standard reference for noncancerous foci), and the average fluorescence intensity of each ROI was calculated both on the RFP and the GmSA-1ROX or GmSA-20ROX spectral unmixed images using commercial software (Maestro software version 2). The number of ROIs drawn in the noncancerous areas was almost the same as that drawn in the cancer foci. All visible nodules with short-axis diameters of
0.8 mm on RFP spectral unmixed images were included for analysis because the minimum possible diameter of a ROI with this software is 0.8 mm. Then, additional ROIs were drawn in the nodules depicted only by the spectral unmixed GmSA-1ROX or GmSA-20ROX images to count the number of false-positive lesions. The average fluorescence intensities of false-positive foci were calculated both on the RFP and the GmSA-1ROX or GmSA-20ROX unmixed images. True positives for GmSA-1ROX or GmSA-20ROX were defined as average fluorescence intensity
10 (a.u.), whereas true negatives for GmSA-1ROX or GmSA-20ROX were defined as average fluorescence intensity <10 (a.u.) on the spectral unmixed images. The number of foci positive for both GmSA-1ROX and RFP or GmSA-20ROX and RFP, negative for both GmSA-1ROX and RFP or GmSA-20ROX and RFP, and positive only for GmSA-1ROX or GmSA-20ROX or RFP was counted. Sensitivity of GmSA-1ROX or GmSA-20ROX for the detection of peritoneal cancer foci was defined as the number of peritoneal foci positive for both GmSA-1ROX and RFP or GmSA-20ROX and RFP divided by the number of peritoneal foci positive for RFP. Specificity of GmSA-1ROX or GmSA-20ROX was defined as the number of peritoneal foci negative for both RFP and GmSA-1ROX or RFP and GmSA-20ROX divided by the number of peritoneal foci negative for RFP.
| Results |
|---|
|
|
|---|
|
In vitro chemical analysis for activation
Signal intensity from both GmSA-20ROX and GmSA-1ROX decreased and their emission peaks shifted toward longer wavelengths under acidic condition. Spectra of GmSA-1ROX at pH 3.3, 5.2, 6.4, and 7.4 contained an emission peak at a wavelength of 610 nm, whereas at pH 2.3 the spectrum contained an emission peak at a wavelength of 620 nm when stepped in 10-nm increments (Fig. 2A
). Spectra of GmSA-20ROX at pH 5.2, 6.4, and 7.4 contained an emission peak at a wavelength of 610 nm, whereas at pH 2.3 and 3.3 the spectra contained an emission peak at a wavelength of 620 nm (Fig. 2A). The fluorescence signal intensity of GmSA-1ROX changed little, whereas the intensity of GmSA-20ROX was lower overall and decreased further under highly acidic conditions (Fig. 2A). The fluorescence intensities of GmSA-1ROX at pH 2.3, 3.3, 5.2, 6.4, and 7.4 were 151, 225, 231, 227, and 213 a.u. and those of GmSA-20ROX were 41, 75, 93, 152, and 146 a.u., respectively (Fig. 2A). When the regression lines were calculated as a function of pH values, the slopes of GmSA-1ROX and GmSA-20ROX were 0.023 and 0.105, respectively. These results indicate that the fluorescence intensity of GmSA-1ROX is higher than that of GmSA-20ROX under the same dose and the same acidic conditions, but the fluorescence intensity of GmSA-20ROX is more strongly quenched by acidic conditions.
|
SDS can activate the fluorescence signal of GmSA-20ROX 16-fold greater than that of GmSA-1ROX. Because enzymatic activation of GmSA-1ROX or GmSA-20ROX was slow and limited compared with the observed activation of GmSA-20ROX in SHIN3 cells, activation was induced by adding a detergent, SDS. SDS (5%) activated GmSA-20ROX signal from 21 (a.u.) to 624 (a.u.), whereas GmSA-1ROX was activated from 29 (a.u.) to 52 (a.u.; Fig. 2C). The activation happened immediately after mixing SDS with samples and was stable at least for 30 min.
This quick and intense activation of GmSA-20ROX with addition of SDS can be captured by video (Supportive video 1) and is most similar to the activation observed after the intracellular activation of GmSA-20ROX as shown in Fig. 1.
In vivo imaging of peritoneal metastasis with activatable GmSA-20ROX probe
GmSA-20ROX produces higher target to background fluorescence within tumor nodules in vivo than GmSA-1ROX. Immediately after i.p. injection with GmSA-1ROX or GmSA-20ROX, the fluorescence intensity of GmSA-20ROX was comparable with that of GmSA-1ROX, but tumor nodules were hard to detect due to free complex in the peritoneal cavity (Fig. 3A
). By 1 h after i.p. injection, the fluorescence intensity arising from tumor nodules using GmSA-20ROX was higher than GmSA-1ROX and the background signal was comparable. By 3 h after injection, the fluorescence intensity of the tumor nodules was visually higher with GmSA-20ROX than with GmSA-1ROX (Fig. 3A). Although a small amount of fluorescence was noted from biliary excretion after i.p. injection with GmSA-20ROX due to transperitoneal systemic absorption, the peritumoral background signal was comparable between the two groups. Submillimeter cancer foci were clearly visualized by close-up imaging of the peritoneal membranes (Fig. 3A).
|
Sensitivity of GmSA-20ROX for the detection of RFP-labeled cancer foci was superior to GmSA-1ROX. Sensitivity and specificity of spectrally unmixed imaging to detect peritoneal cancer foci were compared between GmSA-1ROX and GmSA-20ROX using RFP-transfected SHIN3 cancer cells. Both unmixed GmSA-1ROX and GmSA-20ROX images showed ring-like accumulation around the cancer foci, which were depicted by the unmixed RFP images (Fig. 4
). RFP-positive foci (positive standard) were defined as those whose fluorescence intensities were
30 (a.u.) on unmixed RFP images, and GmSA-ROX–positive foci were defined as those whose fluorescence intensities were
10 (a.u.) on unmixed GmSA-1ROX images or GmSA-20ROX images. Forty-nine foci showed GmSA-1ROX fluorescence intensities
10 (a.u.) among the 207 RFP-positive foci >0.8 mm in diameter (Fig. 4). One hundred eighty-one foci showed GmSA-1ROX fluorescence intensities <10 (a.u.) among the 181 RFP-negative foci [i.e., fluorescence intensities <30 (a.u.) on unmixed RFP images]. Thus, the spectral unmixed GmSA-1ROX image had a sensitivity of 24% (49 of 207) and a specificity of 100% (181 of 181). In contrast, unmixed GmSA-20ROX images showed that 189 foci showed GmSA-20ROX fluorescence intensities
10 (a.u.) among the 190 RFP-positive foci (Fig. 4). One hundred forty-four foci showed GmSA-20ROX fluorescence intensities <10 (a.u.) among the 146 RFP-negative foci. Thus, the spectrally unmixed GmSA-20ROX imaging had a sensitivity of 99% (189 of 190) and a specificity of 99% (144 of 146).
|
| Discussion |
|---|
|
|
|---|
Although the original fluorescence intensity of GmSA-20ROX was almost two thirds of GmSA-1ROX in PBS, GmSA-20ROX images immediately after i.p. injection were unsatisfactory compared with GmSA-1ROX (Fig. 1). Background signals of GmSA-20ROX were higher, resulting in limited target-to-background ratios (Fig. 3A). One of the reasons is that ascites or serum can also partially activate the fluorescence of GmSA-20ROX (Supplementary Fig. S1). Although the explanation for this phenomenon is unclear, it may be due to an energy transfer from nonfluorescent dimers to excited monomers of the dye due to incomplete unfolding of GmSA-20ROX related to the high protein concentration (5, 17).
The strategy of signal activation by selective binding, internalization, and catabolism and/or metabolism leading to dequenching can be applied to a wide variety of targets on the surface of cancer cells (5, 6). Although we studied the D-galactose receptor on SHIN3 ovarian cancer cells using GmSA, similar unfolding activation strategies could be used with other hydrophilic protein ligands (7). Therefore, by changing the targeting moiety, this strategy can be widely applied to other targets or receptors that are expressed on cancer cells.
We foresee that GmSA-20ROX could be readily used in the operating room by surgeons during cytoreductive surgery for ovarian cancer. Because rhodamineX emits in the visible range of light, surgeons will be able to detect fluorescence from small metastatic ovarian cancer nodules using only glasses fitted with appropriate filters and green excitation light. In the event that this is insufficient for detecting all lesions, it is also possible to augment the detected signal using a fluorescence charge-coupled device camera equipped with specific filters, which would display images in real time during the surgery. Using either approach, the specific fluorescence signal from the target tumors could be used to identify small foci of cancer within the peritoneal cavity and reveal local residual disease that would otherwise escape attention.
In conclusion, a newly synthesized target-specific activatable probe GmSA-20ROX was able to identify tiny foci of peritoneal metastases by binding to D-galactose receptors on the surface membrane of ovarian cancer cells. Within 1 h of incubation with GmSA-20ROX, the agent was internalized into cancer cells and produced high intensity fluorescence. Using a RFP counterstain, GmSA-20ROX showed a 99% sensitivity for peritoneal metastases 0.8 mm or greater in size and had a 99% specificity. This agent may be useful in improving the tumor resection in clinical trials of patients with peritoneal metastases who are undergoing cytoreductive surgery.
| Footnotes |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Note: Supplementary data for this article are available at Clinical Cancer Research Online (http://clincancerres.aacrjournals.org/).
3 http://rsb.info.nih.gov/ij/plugins/mri-analysis.html ![]()
Received 4/27/07; revised 7/13/07; accepted 8/ 2/07.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M. Ogawa, C. A.S. Regino, P. L. Choyke, and H. Kobayashi In vivo target-specific activatable near-infrared optical labeling of humanized monoclonal antibodies Mol. Cancer Ther., January 1, 2009; 8(1): 232 - 239. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Cancer Research | Clinical Cancer Research |
| Cancer Epidemiology Biomarkers & Prevention | Molecular Cancer Therapeutics |
| Molecular Cancer Research | Cancer Prevention Research |
| Cancer Prevention Journals Portal | Cancer Reviews Online |
| Annual Meeting Education Book | Meeting Abstracts Online |